Welcome Our Company!
SIEMENS (VL 160X) 160 AMP MCCB
SIEMENS (VL 160X) 160 AMP MCCB

SIEMENS (VL 160X) 160 AMP MCCB

MOQ : 100 Pieces

SIEMENS (VL 160X) 160 AMP MCCB Specification

  • Breaking Capacity
  • 36 kA at 415V AC
  • Phase
  • Three Phase
  • Rated Short Circuit Making Current
  • 72 kA
  • Mechanical Life
  • Up to 20,000 operations
  • Rated Short Circuit Breaking Current
  • 36 kA
  • Product Type
  • Moulded Case Circuit Breaker (MCCB)
  • Installation Options
  • Panel Mount
  • Function
  • Overload and Short Circuit Protection
  • Poles Number
  • 3 Pole
  • Rated Voltage
  • 415V AC
  • Rated Current
  • 160 Amp
  • Rated Frequency
  • 50/60 Hz
  • Curves
  • C, D (Standard, High Magnetic)
  • Temperature Protection
  • Yes (Thermal-magnetic release)
  • Weight
  • Approx. 2.6 kg
  • Color
  • Black / Grey
  • Trip Unit
  • Thermal-Magnetic Fixed
  • Utilization Category
  • AC-23A
  • Conformity Standards
  • IEC 60947-2
  • Mounting Orientation
  • Any
  • Degree of Protection
  • IP20
  • Terminal Type
  • Box Terminals
  • Auxiliary Contact Provision
  • Available (Optional)
  • Ambient Temperature Range
  • -25C to +70C
 

SIEMENS (VL 160X) 160 AMP MCCB Trade Information

  • Minimum Order Quantity
  • 100 Pieces
  • Supply Ability
  • 100 Pieces Per Day
  • Delivery Time
  • 2 Days
  • Sample Available
  • Yes
  • Main Domestic Market
  • All India
 

About SIEMENS (VL 160X) 160 AMP MCCB

MCCB stands forMolded Case Circuit Breaker. It is another type of electrical protection device which is used when load current exceeds the limit of a miniature circuit breaker. The MCCB provides protection against overload, short circuit faults and is also used for switching the circuits.

Superior Protection Mechanism

Equipped with overload and short circuit protection, the VL 160X MCCB safeguards electrical installations against potentially damaging current surges. Its thermal-magnetic fixed trip unit ensures reliable and quick response to both moderate and severe faults, minimizing downtime and equipment damage in industrial and commercial settings.


Flexible Installation and Usage

Designed for ease of use, the MCCB supports installation on panels and can be mounted in any orientation. The box terminal design streamlines wiring, while optional auxiliary contact provision enhances system monitoring. With an ambient temperature range of -25C to +70C, it adapts to diverse operational environments.


Durability and Performance

Built for endurance, the VL 160X features a mechanical life of up to 20,000 operations. Its IP20 degree of protection safeguards internal components, and a high breaking capacity of 36 kA at 415V AC ensures reliable operation amid high fault conditions. The MCCBs performance curve options, C and D, accommodate both standard and high-magnetic requirements.

FAQs of SIEMENS (VL 160X) 160 AMP MCCB:


Q: How does the SIEMENS VL 160X MCCB protect electrical circuits?

A: The VL 160X MCCB provides overload and short-circuit protection using a thermal-magnetic fixed trip unit. It detects excessive current or faults and isolates the affected circuit quickly, minimizing risks of equipment damage and fire.

Q: What are the installation options available for the VL 160X MCCB?

A: This MCCB supports panel mounting and can be installed in any orientation. The box terminals facilitate straightforward wiring, making it suitable for a wide range of distribution panels and control boards.

Q: When is it beneficial to use the auxiliary contact provision in this MCCB?

A: Auxiliary contacts are beneficial when remote monitoring or control of the MCCB status is required. They allow integration with automation systems, indicating breaker position or signaling trips to supervisory equipment.

Q: Where can the VL 160X MCCB be effectively utilized?

A: It is ideal for industrial, commercial, and utility installations requiring reliable protection for three-phase systems at 415V AC, particularly where high fault levels and robust operational demands exist.

Q: What are the advantages of the thermal-magnetic trip unit in the VL 160X MCCB?

A: The thermal-magnetic trip unit provides precise automatic protection against excessive current due to both overloads and short-circuit conditions, enhancing system safety and reliability.

Q: How do the different curve options (C and D) benefit specific applications?

A: Curve C suits standard load conditions, while curve D is designed for high magnetic applications, such as protection of circuits with large induction motors, delivering optimal fault response for diverse requirements.

Q: Is the VL 160X MCCB suitable for use in extreme temperature environments?

A: Yes, it operates reliably within an ambient temperature range of -25C to +70C, making it suitable for both hot and cold climates.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in MCCB(Molded Case Circuit Breaker) Category

ABB MCCB 160A

ABB MCCB 160A

Price Range 50.00 - 500.00 INR / Piece

Minimum Order Quantity : 100 Pieces

Temperature Protection : Yes

Breaking Capacity : 36kA

Function : Overload and Short Circuit Protection

Rated Voltage : 415V AC

MITSUBISHI MCCB - 125A

MITSUBISHI MCCB - 125A

Price Range 50.00 - 500.00 INR / Piece

Minimum Order Quantity : 100 Pieces

Temperature Protection : Yes (ThermalMagnetic)

Breaking Capacity : 36 kA

Function : Protection against overload & short circuit

Rated Voltage : 415V AC

ABB SACE TMAX 8A 3P MCCB

ABB SACE TMAX 8A 3P MCCB

Minimum Order Quantity : 10 Pieces

Temperature Protection : Yes, builtin thermal protection

Breaking Capacity : 25 kA at 415V AC

Function : Protection against overload and short circuit

Rated Voltage : 415V AC

CandS New 60A 3P MCCB

CandS New 60A 3P MCCB

Minimum Order Quantity : 5 Pieces

Temperature Protection : Yes

Breaking Capacity : 25kA

Function : Overload & Short Circuit Protection

Rated Voltage : 415V AC



Back to top