LT (DTH 400) 400A 3P MCCB Specification

  • Rated Short Circuit Breaking Current
  • 36 kA @ 415V AC
  • Breaking Capacity
  • 36 kA
  • Phase
  • Three Phase
  • Mechanical Life
  • 10,000 Operations
  • Rated Short Circuit Making Current
  • 88 kA Peak
  • Product Type
  • Moulded Case Circuit Breaker (MCCB)
  • Installation Options
  • Panel Mounting
  • Function
  • Overcurrent and Short Circuit Protection
  • Poles Number
  • 3P
  • Rated Voltage
  • 415V AC
  • Rated Current
  • 400A
  • Rated Frequency
  • 50/60 Hz
  • Curves
  • Type C
  • Temperature Protection
  • Thermal & Magnetic Release
  • Weight
  • Approx. 3.5 kg
  • Color
  • Black and Grey
  • Ambient Temperature Range
  • -5C to +55C
  • Operating Voltage
  • 220/240V to 415V AC
  • Auxiliary Contacts
  • Optional
  • Trip Unit
  • Thermal Magnetic
  • Service Life
  • Long Service Life
  • Standards
  • IEC 60947-2
  • Mounting Position
  • Vertical/Horizontal
  • IP Rating
  • IP20 (Front)
 

LT (DTH 400) 400A 3P MCCB Trade Information

  • Minimum Order Quantity
  • 3 Pieces
  • Payment Terms
  • Cash in Advance (CID), Cheque, Letter of Credit (L/C)
  • Sample Available
  • Yes
  • Main Export Market(s)
  • Asia, Middle East, Africa
  • Main Domestic Market
  • All India
 

About LT (DTH 400) 400A 3P MCCB

L&T (DTH 400) 400A 3P MCCB Available In Stock At Raj Electricals, Bhavnagar, Gujarat, India.

We are engaged in the supply, dealing, distribution, export and import of the widest range of electrical and electronic items that would suit every type of project, economy and medium.

Product Specification :-

Type :- MCCB (Moulded Case Circuit Breaker)

Make :- L&T

Ampere :- 400

Pole :- 3P

Model :- DTH 400

Condition :- Refurbished

Breaking Capacity :- 50 kA

Voltage :- 415V AC

Frequency :- 50-60 Hz

For More Details

WhatsApp or call on :- +919426838080, +919904838080.

YouTube : https://www.youtube.com/@rajelectricals5253

Google : https://g.co/kgs/WCmt5a

Instagram : https://www.instagram.com/rajelectric52/

Facebook : https://www.facebook.com/RajElectricals52/

Website : https://www.rajelectrics.com/



Advanced Electrical Protection

The MCCB employs a thermal magnetic trip unit, providing dual protection against both overloads and short circuits. Its breaking capacity of 36 kA ensures quick and safe interruption of excessive currents, safeguarding both equipment and personnel in critical environments.


Flexible Installation and Operation

Designed for versatility, the MCCB supports both panel mounting and multiple orientations-vertical or horizontal. Auxiliary contacts can be added as needed for monitoring or automation, making it suitable for a wide range of industrial and commercial installations.


Built for Durability and Reliability

With a rated current of 400A and a mechanical life of up to 10,000 operations, this MCCB delivers consistent performance even in demanding conditions. Its long service life and compliance with IEC 60947-2 standards further enhance operational reliability.

FAQ's of LT (DTH 400) 400A 3P MCCB:


Q: How does the LT (DTH 400) 400A 3P MCCB provide protection in electrical installations?

A: It uses a thermal magnetic trip unit to detect and interrupt abnormal currents such as overloads and short circuits, thus preventing damage to connected equipment and improving system safety.

Q: What are the installation options for this MCCB?

A: The device can be mounted on a panel and allows for both vertical and horizontal mounting positions, accommodating various installation requirements.

Q: When is this MCCB ideally used in an electrical system?

A: It is suitable for three-phase networks in industrial, commercial, or utility applications where robust overcurrent and short circuit protection up to 36 kA is essential.

Q: Where can the LT (DTH 400) 400A 3P MCCB be applied?

A: This MCCB is primarily used in power distribution panels, control centers, and other setups demanding high-reliability circuit protection in environments within -5C to +55C ambient temperature.

Q: What is the process for integrating auxiliary contacts with this MCCB?

A: Optional auxiliary contacts can be installed alongside the MCCB for remote status monitoring or interface with automation systems, enhancing control and diagnostics.

Q: What are the operational benefits of using this MCCB?

A: It offers long service life, high breaking and making capacities, reliable protection, and ease of maintenance-making it a dependable choice for professional electrical applications.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in MCCB(Molded Case Circuit Breaker) Category

MITSUBISHI (NF 630-SE) 630 AMP MCCB

MITSUBISHI (NF 630-SE) 630 AMP MCCB

Price Range 50.00 - 500.00 INR / Piece

Minimum Order Quantity : 100 Pieces

Temperature Protection : Thermal Trip Adjustment

Rated Short Circuit Breaking Current : 50 kA at 415V AC

Rated Frequency : 50/60 Hz

Rated Current : 630 Ampere

SIEMENS MCCB - 400A

SIEMENS MCCB - 400A

Price Range 50.00 - 500.00 INR / Piece

Minimum Order Quantity : 100 Pieces

Temperature Protection : Inbuilt thermal and magnetic release

Rated Short Circuit Breaking Current : 36 kA

Rated Frequency : 50/60 Hz

Rated Current : 400A

LT NEW (DU250C) 250A 4P MCCB

LT NEW (DU250C) 250A 4P MCCB

Minimum Order Quantity : 3 Pieces

Temperature Protection : Yes (ThermalMagnetic Release)

Rated Short Circuit Breaking Current : 36kA (Icu)

Rated Frequency : 50/60Hz

Rated Current : 250A

HYUNDAI (HBS-63C) 20A 3P MCCB

HYUNDAI (HBS-63C) 20A 3P MCCB

Minimum Order Quantity : 10 Pieces

Temperature Protection : ThermalMagnetic Trip Unit

Rated Short Circuit Breaking Current : 25kA

Rated Frequency : 50/60 Hz

Rated Current : 20A



Back to top