SIEMENS (VL 400) 315 AMP MCCB Specification

  • Rated Short Circuit Breaking Current
  • 50 kA
  • Rated Short Circuit Making Current
  • 105 kA
  • Mechanical Life
  • 20,000 Operations
  • Phase
  • Three Phase
  • Breaking Capacity
  • 50 kA
  • Product Type
  • Molded Case Circuit Breaker (MCCB)
  • Installation Options
  • Fixed, Plug-in, or Withdrawable
  • Function
  • Overload and Short Circuit Protection
  • Poles Number
  • 3P
  • Rated Voltage
  • 415V AC
  • Rated Current
  • 315 Amp
  • Rated Frequency
  • 50/60 Hz
  • Curves
  • C & D Curves available
  • Temperature Protection
  • Integrated Adjustable Thermal Protection
  • Weight
  • Approx. 6.5 kg
  • Color
  • Grey/Black
 

SIEMENS (VL 400) 315 AMP MCCB Trade Information

  • Minimum Order Quantity
  • 100 Pieces
  • Supply Ability
  • 100 Pieces Per Day
  • Delivery Time
  • 2 Days
  • Sample Available
  • Yes
  • Main Domestic Market
  • All India
 

About SIEMENS (VL 400) 315 AMP MCCB

MCCB stands forAA Molded Case Circuit Breaker. It is another type of electrical protection device which is used when load current exceeds the limit of a miniature circuit breaker. The MCCB provides protection against overload, short circuit faults and is also used for switching the circuits.

Versatile Installation

The SIEMENS (VL 400) 315 AMP MCCB accommodates various installation needs, supporting fixed, plug-in, and withdrawable options. Its front terminal connection and compatibility with both vertical and horizontal positions allow for flexibility in electrical panel design, simplifying integration regardless of your project's requirements.


Advanced Protection Features

This MCCB is equipped with integrated adjustable thermal protection and a robust thermal magnetic trip unit. With a protection level of IP20, it guards against accidental contact, while its overload and short circuit protection capabilities safeguard your systems and ensure uninterrupted operations in demanding environments.

FAQ's of SIEMENS (VL 400) 315 AMP MCCB:


Q: How does the SIEMENS (VL 400) 315 AMP MCCB provide overload and short circuit protection?

A: The SIEMENS (VL 400) MCCB uses a thermal magnetic trip unit, which detects sustained overloads with its thermal component and instantly reacts to short circuits using its magnetic component, thereby protecting the system and connected devices from electrical hazards.

Q: What are the possible installation options for the SIEMENS (VL 400) 315 AMP MCCB?

A: This MCCB can be installed in fixed, plug-in, or withdrawable configurations with a front terminal connection, offering adaptability for various electrical installations. It can also be mounted either vertically or horizontally to fit different panel designs.

Q: When should a C or D curve be chosen for this MCCB?

A: C curve MCCBs are ideal for general purpose circuits with moderate inrush currents, while D curve versions are better for circuits with high inrush currents, such as those powering motors or transformers. The choice depends on the nature of the load in your application.

Q: Where can the SIEMENS (VL 400) 315 AMP MCCB be deployed?

A: This device is suitable for industrial, commercial, and infrastructural settings that require high-breaking capacity and reliable protection, functioning effectively in ambient temperatures from -25C to +70C and supporting three-phase, 415V AC systems.

Q: What benefits does the adjustable thermal protection provide?

A: The integrated adjustable thermal protection allows users to set the protection threshold based on load requirements, enhancing safety and helping to reduce unnecessary tripping, thus improving operational continuity and equipment lifespan.

Q: How often does the MCCB require maintenance or replacement?

A: With a mechanical life of approximately 20,000 operations and 8,000 electrical endurance cycles, the SIEMENS (VL 400) MCCB is engineered for long-term reliability. Regular inspection and testing are recommended as part of standard maintenance protocols in industrial environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in MCCB(Molded Case Circuit Breaker) Category

HYUNDAI MCCB - 50A

HYUNDAI MCCB - 50A

Minimum Order Quantity : 100 Pieces

Rated Frequency : 50/60 Hz

Color : Gray/Black

Phase : Three Phase

Poles Number : Other, 3 Pole

ABB (SACE S4N) 250A 3P MCCB

ABB (SACE S4N) 250A 3P MCCB

Price 1 INR / Number

Minimum Order Quantity : 3 Pieces

Rated Frequency : 50/60 Hz

Color : Grey

Phase : Three Phase

Poles Number : Other, 3 Poles

LT NEW (DU250C) 160A 3P MCCB

LT NEW (DU250C) 160A 3P MCCB

Price 1 INR / Number

Minimum Order Quantity : 5 Pieces

Rated Frequency : 5060 Hertz (HZ)

Color : White

Phase : Three Phase

Poles Number : 3

LG 700A 3P MCCB

LG 700A 3P MCCB

Price 1 INR / Number

Minimum Order Quantity : 1 Piece



Back to top